C3102 (bizhub C754e/C654e)

You are here:

Contents

Trouble typeHeating roller failure to turn
Trouble codeC3102
RankA
Detection timingDuring any state other than printing operation , the hard latch signal from one or both of the heating roller rotation latch detection 1 and the heating roller rotation latch detection 2 is turned ON.
Trouble isolation
Relevant electrical parts• Heating roller rotation sensor (PS56)
• Fusing motor (M30)
• Printer control board (PRCB)
• A0P0M11500 Fusing unit

 (2)Procedure

StepActionControl signalLocation of electrical components
1Check the fusing unit for proper installation and correct as necessary.
2Check the connector between M30-PRCB CN30 for proper connection and correct as necessary.
3Check the connector of M30 for proper drive coupling and correct as necessary.
4PS56 I/O check, sensor check
5M30 operation checkPRCB CN30-4 (REM)PRCB CN30-7 (LOCK)4-K
6PRCB ICP15 conduction check

7Replace M30 (Part# A0P0M11500)
8Replace the fusing unit (Part# A2X0R71055)
9Replace PRCB (Part# A2X0H00S06)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.8.2 (Link to the Field Service Manual)