How Can We Help?

C3103 (bizhub 658e/558e/458e)

You are here:

Contents

Trouble typeC3103: Pressure roller release failure
RankB
Trouble detection condition• The encoder pulse does not change even after the lapse of a predetermined period of time after the fusing pressure motor (M11) has started rotating during retraction of the pressure roller.
• The fusing pressure home sensor (PS38) is not unblocked even after the lapse of a predetermined period of time after the fusing pressure motor (M11) has started rotating during retraction of the pressure roller.
Trouble isolation
Relevant electrical parts• Fusing unit 
• Fusing pressure motor (M11) 
• Fusing pressure home sensor (PS38) 
• MFP board (MFPB)

 Procedure

  1. Check the connector between M11-relay CN112-MFPB CN15E for proper connection and correct as necessary.
  2. Check the connector between the fusing unit-relay CN96-MFPB CN22E for proper connection and correct as necessary. (bizhub 658e/558e)
  3. Check the connector between the fusing unit-relay CN104-MFPB CN12E for proper connection and correct as necessary. (bizhub 458e)
  4. PS38 I/O check, sensor check
    • Control signal: 658e/558e MFPB CN22E-9 (ON), 458e MFPB CN12E-12 (ON)
    • Location of electrical component: 658e/558e 22-C, 458e 24-C
  5. M11 load check
    • Check code: 45
    • Multi code: 6, 7
    • Control signal: MFPB CN15E<A>-7 to 10
    • Location of electrical component: 658e/558e 16-C, 458e 19-C
  6. Replace M11. (Part# A161M10300)
  7. Replace the fusing unit. (bizhub 658e/558e Part# A79JR71077 / bizhub 458e Part# AA6UR70400)
  8. Replace MFPB. (658e/558e Part# AA6RH02103 / 458e Part# AA6UH02101)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

L.3.12.1 (Link to the Field Service Manual)

Table of Contents