C3103 (bizhub C658/C558/C458)

You are here:

Contents

Trouble typeC3103: Pressure roller release failure
RankB
Trouble detection condition• The encoder pulse does not change even after the lapse of a predetermined period of time after the fusing pressure motor (M11) has started rotating during retraction of the pressure roller.
• The fusing pressure home sensor (PS38) is not unblocked even after the lapse of a predetermined period of time after the fusing pressure motor (M11) has started rotating during retraction of the pressure roller.
Trouble isolation
Relevant electrical parts• Fusing unit
• Fusing pressure motor (M11)
• Fusing pressure home sensor (PS38)
• MFP board (MFPB)

 Procedure

  1. Check the connector between M11-relay CN112-MFPB CN15E for proper connection and correct as necessary.
  2. Check the connector between the fusing unit-relay CN96-MFPB CN22E for proper connection and correct as necessary. (bizhub C658/C558)
  3. Check the connector between the fusing unit-relay CN104-MFPB CN12E for proper connection and correct as necessary. (bizhub C458)
  4. PS38 I/O check, sensor check
    • Control signal: C658/C558 MFPB CN22E-9 (ON), C458 MFPB CN12E-12 (ON)
    • Location of electrical component: C658/C558 22-C, C458 24-C
  5. M11 operation check
    • Control signal: MFPB CN15E<A>-7 to 10
    • Location of electrical component: C658/C558 16-C, C458 19-C
  6. Replace M11.(Part# A161M10300)
  7. Replace the fusing unit. (bizhub C658/C558 Part# A79JR71066 / bizhub C458 Part# A79MR70222)
  8. Replace MFPB. (C458 Part# A79MH02102 / C558 or C658 Part # A79JH02102)

NOTICE

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.14.1 (Link to the Field Service Manual)

Table of Contents