Trouble type Fusing motor failure to turn
Trouble code C3201
Rank B
Detection timing The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
Trouble isolation
Relevant electrical parts • Fusing motor (M3)
• Printer control board (PRCB)

  (2)Procedure

StepActionControl signalLocation of electrical components
1Check the connector between M3-PRCB CN2 for proper connection and correct as necessary.
2Check the loading status of the fusing unit drive, and correct the error as necessary.
3M3 operation checkPRCB CN2-9 (REM)PRCB CN2-12 (LOCK)bizhub 554e 22-Jbizhub 454e 21-J
4Replace M3 (Part# A161M10300)
5Replace PRCB (554e Part# A61EH00101 / 454e Part# A61DH00101)

Document Information ID D0001134367 Revise ID R000003