C3201 (bizhub C754/C654)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | Fusing motor’s failure to turn |
Trouble code | C3201 |
Rank | B |
Detection timing | The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning. |
Trouble isolation | – |
Relevant electrical parts | -Fusing motor (M30) -Printer control board (PRCB) |
 (2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | Check the connector between M30-PRCB CN30for proper connection and correct as necessary. | – | – |
2 | Check the loading status of the fusing unit drive, and correct the error as necessary. | – | – |
3 | M30 operation check | PRCB CN30-4 (REM)PRCB CN30-7 (LOCK) | 4-K |
4 | Replace M30 (Part# A0P0M11500) | – | – |
5 | PRCB ICP9 conduction check | – | – |
6 | Replace PRCB (Part# A2X0H00102) | – | – |
- Link to the wiring diagram (N.1. bizhub C754/C654)
- Link to the layout drawings for related parts by each trouble code (S.69. C3201, C3202)
K.3.8.3 (Link to the Field Service Manual)