How Can We Help?

C3202 (bizhub C754/C654)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeFusing motor’s turning at abnormal timing
Trouble codeC3202
RankB
Detection timingThe motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Trouble isolation
Relevant electrical parts-Fusing motor (M30)
-Printer control board (PRCB)

(2)Procedure

StepActionControl signalLocation of electrical components
1Check the connector between M30-PRCB CN30for proper connection and correct as necessary.
2Check the loading status of the fusing unit drive, and correct the error as necessary.
3M30 operation checkPRCB CN30-4 (REM)PRCB CN30-7 (LOCK)4-K
4Replace M30 (Part# A0P0M11500)
5PRCB ICP9 conduction check
6Replace PRCB (Part# A2X0H00102)

K.3.8.3 (Link to the Field Service Manual)