C3202 (bizhub 558/458)
Contents
Trouble type | C3202: Fusing motor’s turning at abnormal timing |
Rank | B |
Trouble detection condition | The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary. |
Trouble isolation | – |
Relevant electrical parts | • Fusing motor (M3) • MFP board (MFPB) |
Procedure
- Check the connector between M3-MFPB CN14E for proper connection and correct as necessary.
- Check the loading status of the fusing unit drive, and correct the error as necessary.
- M3 operation check
- Control signal: MFPB CN14E-9 (REM), MFPB CN14E-12 (LOCK)
- Location of electrical component: 2-C
- Replace M3. (Part# A79JM11300)
- Replace MFPB. (558 Part# A9HGH02102 / 458 Part# A9HHH02102)
NOTICE
- Link to the wiring diagram (bizhub 558/458)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.13.3 (Link to the Field Service Manual)