How Can We Help?
C3202 (bizhub 658e/558e/458e)
Contents
Trouble type | C3202: Fusing motor turning at abnormal timing |
Rank | B |
Trouble detection condition | The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary. |
Trouble isolation | – |
Relevant electrical parts | • Fusing motor (M3) • MFP board (MFPB) |
Procedure
- Check the connector between M3-MFPB CN14E for proper connection and correct as necessary.
- Check the loading status of the fusing unit drive, and correct the error as necessary.
- M3 load check
- Check code: 45
- Multi code: 1, 2, 3, 4, 5
- Control signal: MFPB CN14E-9 (REM), MFPB CN14E-12 (LOCK)
- Location of electrical component: 2-C
- Replace M3. (Part# A79JM10300)
- Replace MFPB. (658e/558e Part# AA6RH02103 / 458e Part# AA6UH02101)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
L.3.12.3 (Link to the Field Service Manual)