How Can We Help?

C3202 (bizhub 658e/558e/458e)

You are here:

Contents

Trouble typeC3202: Fusing motor turning at abnormal timing
RankB
Trouble detection conditionThe motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Trouble isolation
Relevant electrical parts• Fusing motor (M3) 
• MFP board (MFPB)

 Procedure

  1. Check the connector between M3-MFPB CN14E for proper connection and correct as necessary.
  2. Check the loading status of the fusing unit drive, and correct the error as necessary.
  3. M3 load check
    • Check code: 45
    • Multi code: 1, 2, 3, 4, 5
    • Control signal: MFPB CN14E-9 (REM), MFPB CN14E-12 (LOCK)
    • Location of electrical component: 2-C
  4. Replace M3. (Part# A79JM10300)
  5. Replace MFPB. (658e/558e Part# AA6RH02103 / 458e Part# AA6UH02101)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.