How Can We Help?

C3302 (bizhub 368e/308e)

You are here:

Contents

Trouble typeC3302: Paper cooling fan failure to turn
RankB
Trouble detection conditionThe fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Trouble isolation
Relevant electrical parts• Paper cooling fan (FM8)
• MFP board (MFPB)

 Procedure

  1. Check the connector between FM8-relay CN106-MFPB CN15EB for proper connection and correct as necessary.
  2. Check the fan for possible overload and correct as necessary.
  3. FM8 load check
    • Check code: 42
    • Multi code: 4
    • Control signal: MFPB CN15EB-9 (REM), MFPB CN15EB-11 (LOCK)
    • Location of electrical component: 9-C
  4. Replace FM8. (Part# 9313100072)
  5. MFPB ICP3E conduction check
  6. Replace MFPB. (Part# AA6VH02101)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

L.3.11.3https://wapps.mykonicaminolta.com/msman/m/service/bizhub658eservice/en-US/4780446347.html (Link to the Field Service Manual)