C3302 (bizhub 658e/558e/458e)

You are here:

Contents

Trouble typeC3302: Paper cooling fan failure to turn
RankB
Trouble detection conditionThe fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Trouble isolation
Relevant electrical parts• Paper cooling fan (FM8)
• MFP board (MFPB)

 Procedure

  1. Check the connector between FM8-relay CN106-MFPB CN15E for proper connection and correct as necessary.
  2. Check the fan for possible overload and correct as necessary.
  3. FM8 load check
    • Check code: 42
    • Multi code: 9, 10
    • Control signal: MFPB CN15E<A>-13 (REM), MFPB CN15E<A>-15 (LOCK)
    • Location of electrical component: 658e/558e 16-C, 458e 20-C
  4. Replace FM8. (Part# 9313100072)
  5. Replace MFPB. (658e/558e Part# AA6RH02103 / 458e Part# AA6UH02101)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

L.3.12.4 (Link to the Field Service Manual)