C3202 (bizhub C759/C659)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C3202: Fusing motor turning at abnormal timing |
Rank | B |
Trouble detection condition | The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary. |
Trouble isolation | – |
Relevant electrical parts | -Fusing motor (M30) -MFP board (MFPB) |
Procedure
- Check the connector between M30-MFPB CN28E for proper connection and correct as necessary.
- Check the loading status of the fusing unit drive, and correct the error as necessary.
- M30 load check
- Check code: 45
- Multi code: 1, 2, 3, 4, 5, 6
- Control signal: MFPB CN28E-1 (DC24V), MFPB CN28E-4 (REM), MFPB CN28E-7 (LOCK)
- Location of electrical component: 7-K
- Replace M30. (Part# A796M10200)
- MFPB F16E conduction check
- Replace MFPB. (Part# A8JEH02002)
- DCPU F851 conduction check.
- Replace DCPU. (Part# A795R73722)
L.3.10.3 (Link to the Field Service Manual)