How Can We Help?

C3202 (bizhub C759/C659)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeC3202: Fusing motor turning at abnormal timing
RankB
Trouble detection conditionThe motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Trouble isolation
Relevant electrical parts-Fusing motor (M30)
-MFP board (MFPB)

 Procedure

  1. Check the connector between M30-MFPB CN28E for proper connection and correct as necessary.
  2. Check the loading status of the fusing unit drive, and correct the error as necessary.
  3. M30 load check
    • Check code: 45
    • Multi code: 1, 2, 3, 4, 5, 6
    • Control signal: MFPB CN28E-1 (DC24V), MFPB CN28E-4 (REM), MFPB CN28E-7 (LOCK)
    • Location of electrical component: 7-K
  4. Replace M30. (Part# A796M10200)
  5. MFPB F16E conduction check
  6. Replace MFPB. (Part# A8JEH02002)
  7. DCPU F851 conduction check.
  8. Replace DCPU. (Part# A795R73722)

L.3.10.3 (Link to the Field Service Manual)

Table of Contents