C3303 (bizhub C759/C659)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C3303: Paper cooling fan/out failure to turn |
Rank | B |
Trouble detection condition | The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning. |
Trouble isolation | – |
Relevant electrical parts | -Paper cooling fan/out (FM13) -Process drive board (PDB) |
Procedure
- Check the connector between FM13-relay CN323-PDB CN10 for proper connection and correct as necessary.
- Check the fan for possible overload and correct as necessary.
- FM13 load check
- Check code: 42
- Multi code: 13
- Control signal: PDB CN10-13 (DRIVE), PDB CN10-15 (LOCK)
- Location of electrical component: 19-X
- Replace FM13. (Part# A0P0M14200)
- PDB F4 conduction check
- Replace PDB. (Part# A8JEH00400)
L.3.10.4 (Link to the Field Service Manual)