C3305 (bizhub C759/C659)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
| Trouble type | C3305: Reverse paper cooling fan/1 failure to turn | 
| Rank | B | 
| Trouble detection condition | The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning. | 
| Trouble isolation | – | 
| Relevant electrical parts | -Reverse paper cooling fan/1 (FM4) -Paper feed/transport drive board (PFTDB)  | 
Procedure
- Check the connector between FM4-relay CN283-relay CN280-relay CN279-relay CN271B-PFTDB CN2 for proper connection and correct as necessary.
 - Check the fan for possible overload and correct as necessary.
 - FM4 load check
- Check code: 42
 - Multi code: 14, 15
 - Control signal: PFTDB CN2-13 (REM), PFTDB CN2-15 (LOCK)
 - Location of electrical component: 5-P
 
 - Replace FM4. (Part# 9J06M10000)
 - PFTDB F14 conduction check
 - Replace PFTDB. (Part# A795H00200)
 
L.3.10.6 (Link to the Field Service Manual)