Trouble type | C3310: Output tray exhaust fan failure to turn |
Rank | B |
Trouble detection condition | The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning. |
Trouble isolation | – |
Relevant electrical parts | -Output tray exhaust fan (FM18) -Process drive board (PDB) |
Procedure
- Check the connector between FM18-relay CN701-PDB CN9 for proper connection and correct as necessary.
- Check the fan for possible overload and correct as necessary.
- FM18 load check
- Check code: 42
- Multi code: 25
- Control signal: PDB CN9-9 (DRIVE), PDB CN9-11 (LOCK)
- Location of electrical component: 19-P
- Replace FM18. (Part# A0P0M14200)
- PDB F3 conduction check
- Replace PDB. (Part# A8JEH00400)