C3307 (bizhub C650i/C550i/C450i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C3307: Fusing edge cooling fan/Rr failure to fr turn (bizhub C650i/C550i) |
Rank | B |
Trouble detection condition | The fan lock signal remains Low for a predetermined continuous period of time while the fan is turning. |
Trouble isolation | – |
Relevant electrical parts | -Fusing edge cooling fan/Rr (FM22) -CPU board (CPUB) -Base board (BASEB) |
Procedure
- Check the connector between FM22-relay CN163-relay CN161-BASEB CN22E for proper connection and correct as necessary.
- Check the fan for possible overload and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- FM22 load check
- Check code: 42
- Multi code: 19, 20
- Control signal: BASEB CN22E-16 (REM), BASEB CN22E-18 (LOCK)
- Location of electrical component: 13-C
- Replace FM22. (Part# AA7NM10H00)
- Replace CPUB. (C450i Part# AA7RH02P02 / C550i Part# AA7PH02P01 / C650i Part# AA7NH02P03)
- Replace BASEB. (Part# AA7NH02102)
L.3.10.7 (Link to the Field Service Manual)