Trouble type | C3425: Fusing warm-up trouble |
Rank | A |
Trouble detection condition | -Detected temperature of the heating roller temperature sensor (TEMS) does not go up a given range of temperature even after a lapse of given period of time at warm up. -The temperature detected by the heating roller temperature sensor (TEMS) does not shift from the pre-standby state even after the lapse of a predetermined period of time after the completion of warm-up. |
Trouble isolation | – |
Relevant electrical parts | -Fusing unit -Heating roller temperature sensor (TEMS) -DC power supply (DCPU) -CPU board (CPUB) -Base board (BASEB) |
Procedure
- Check the fusing unit for correct installation (whether it is secured in position).
- Check the open/close operation of the right door.
- Check the connector between the fusing unit-relay CN95, CN96-BASEB CN4E for proper connection and correct as necessary.
- Check the connector between BASEB CN2E-DCPU CN7 for proper connection and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- Replace the fusing unit. (C650i/C550i Part# AA7NR70200 / C450i Part# AA7RR70700)
- Replace CPUB. (C450i Part# AA7RH02P02 / C550i Part# AA7PH02P01 / C650i Part# AA7NH02P03)
- Replace BASEB. (Part# AA7NH02102)
- Replace DCPU. (bizhub C650i/C550i Part# AA7NR71600 / bizhub C450i Part# AA7RR70200)
L.3.10.8 (Link to the Field Service Manual)