C3425 (bizhub 4750i/4050i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C3425: Fusing warm-up trouble |
Rank | A |
Trouble detection condition | – Detected temperature of the heating roller temperature sensor (TEMS) does not go up a given range of temperature even after a lapse of given period of time at warm up. – The temperature detected by the heating roller temperature sensor (TEMS) does not shift from the pre-standby state even after the lapse of a predetermined period of time after the completion of warm-up. |
Trouble isolation | – |
Relevant electrical parts | -Fusing unit -Heating roller temperature sensor (TEMS) -DC power supply (DCPS) -CPU board (CPUB) -Base board (BASEB) |
Procedure
- Check the fusing unit for correct installation (whether it is secured in position).
- Check the open/close operation of the right door.
- Check the connector between the fusing unit-relay CN3-BASEB CN10E for proper connection and correct as necessary.
- Check the connector between the fusing unit-relay CN2-DCPS CN2 for proper connection and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- Replace the fusing unit. (Part# ACT8R70100)
- Replace CPUB. (Part# ACT9H01003)
- Replace BASEB.
4750i (Part# ACT9H02013)
4050i (Part# ACT9H02002)
- DCPS FU181 conduction check
- Replace DCPS. (Part# AAJRR70600)