Detected temperature of the heating roller temperature sensor (TEMS) does not go up a given range of temperature even after a lapse of given period of time at warm up.The temperature detected by the heating roller temperature sensor (TEMS) does not shift from the pre-standby state even after the lapse of a predetermined period of time after the completion of warm-up.
Trouble isolation
–
Relevant electrical parts
Fusing unitHeating roller temperature sensor (TEMS)DC power supply (DCPS)CPU board (CPUB)Base board (BASEB)
Procedure
Check the fusing unit for correct installation (whether it is secured in position).
Check the open/close operation of the right door.
Check the connector between the fusing unit-relay CN3-BASEB CN10E for proper connection and correct as necessary.
Check the connector between the fusing unit-relay CN2-DCPS CN2 for proper connection and correct as necessary.
Check CPUB for proper installation and correct as necessary.