Trouble type Fusing warm-up trouble
Trouble code C3425
Rank A
Detection timing• Detected temperature of the heating roller temperature sensor (TEMS) does not go up a given range of temperature even after a lapse of given period of time at warm up.
• The warm-up is not completed even after the set period of time has elapsed after the warm-up is started.
• Less than the predetermined temperature of the heating roller temperature sensor (TEMS), even after a predetermined period of time after warm-up is complete.
Trouble isolation
Relevant electrical parts• Fusing unit
• Heating roller temperature sensor (TEMS)
• DC power supply (DCPU)
• Printer control board (PRCB)

  (2)Procedure

Step Action Control signal Location of electrical components
1 Check the fusing unit for correct installation (whether it is secured in position).
2 Check the open/close operation of the right door.
3 Check the fusing unit, DCPU and PRCB for proper connection and correct or change as necessary.
4 Replace the fusing unit (bizhub 554e/bizhub 454e) Fusing Unit (Part# 554e A2XKR71022 454e A4FJR70322)
5 Replace PRCBPRCB (Part# 554e A61DH00101 454e A61EH00101)
6 Replace DCPUDCPU (Part# 100v A5AYR70000 200v A5AYR70100)
  • Link to the layout drawings for related parts by each trouble code (S.69. C3425)