C3722 (bizhub 554e/454e)
Contents
Trouble type | Fusing abnormally high temperature detection (Edge of the heating side) |
Trouble code | C3722 |
Rank | A |
Detection timing | Detected temperature of the heating roller thermistor/1 (TH1) goes beyond a given temperature for a given period of time consecutively. |
Trouble isolation | – |
Relevant electrical parts | • Fusing unit • Heating roller thermistor/1 (TH1) • IH power supply (IHPU) (bizhub 554e only) • Printer control board (PRCB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | Check the fusing unit for correct installation (whether it is secured in position). | – | – |
2 | Check the open/close operation of the right door. | – | – |
3 | Check the fusing unit, IHPU (bizhub 554e only) and PRCB for proper connection and correct or change as necessary. | – | – |
4 | Replace the fusing unit (bizhub 554e/bizhub 454e) Fusing Unit (Part# 554e A2XKR71022 454e A4FJR70322) | – | – |
5 | Replace IHPU (bizhub 554e only)IHPU (Part# 554e 100v A61DM40A00 230v A61DM40B00) | – | – |
6 | Replace PRCBPRCB (Part# 554e A61DH00101 454e A61EH00101) | – | – |
- Link to the layout drawings for related parts by each trouble code (S.70. C3722)