How Can We Help?

C3425 (bizhub C658/C558/C458)

You are here:

Contents

Trouble typeC3425: Fusing warm-up trouble
RankA
Trouble detection conditionbizhub C658/C558
• Detected temperature of the heating roller temperature sensor1 (TEMS/1) does not go up a given range of temperature even after a lapse of given period of time at warm up.
• The temperature detected by the heating roller temperature sensor1 (TEMS/1) does not shift from the pre-standby state or the post-print color printing-enable wait state even after the lapse of a predetermined period of time after the completion of warm-up.
bizhub C458
• Detected temperature of the heating roller thermistor1 (TH1) does not go up a given range of temperature even after a lapse of given period of time at warm up.
• The temperature detected by the heating roller thermistor1 (TH1) does not shift from the pre-standby state or the post-print color printing-enable wait state even after the lapse of a predetermined period of time after the completion of warm-up.
Trouble isolation
Relevant electrical parts• Fusing unit
• bizhub C658/C558: Heating roller temperature sensor1 (TEMS/1)
• bizhub C458: Heating roller thermistor1 (TH1)DC power supply (DCPU)
• MFP board (MFPB)

 Procedure

  1. Check the fusing unit for correct installation (whether it is secured in position).
  2. Check the open/close operation of the right door.
  3. Check the fusing unit, DCPU, and MFPB for proper connection and correct or change as necessary.
  4. Replace the fusing unit. (bizhub C658/C558 Part# A79JR71066/ bizhub C458 Part# A79MR70222)
  5. Replace MFPB. (C458 Part# A79MH02102 / C558 or C658 Part # A79JH02102)
  6. Replace DCPU. (Part# A79JR70000)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.14.5 (Link to the Field Service Manual)

Table of Contents