Trouble typeC3722: Fusing abnormally high temperature detection (Edge of the heating roller)
RankA
Trouble detection conditionDetected temperature of the heating roller temperature sensor2 (TEMS/2) or heating roller thermistor1 (TH1) goes beyond a given temperature for a given period of time consecutively
Trouble isolation
Relevant electrical parts• Fusing unit
• (bizhub C658): Heating roller temperature sensor2 (TEMS/2)
• (bizhub C558/C458): Heating roller thermistor1 (TH1)
• IH power supply (IHPU) (bizhub C658/C558 only)
• Fusing power supply (FUPU) (bizhub C458 only)
• MFP board (MFPB)

 Procedure

  1. Check the fusing unit for correct installation (whether it is secured in position).
  2. Check the open/close operation of the right door.
  3. Check the fusing unit-MFPB CN22E for proper connection and correct or change as necessary. (bizhub C658/C558)
  4. Check the fusing unit-MFPB CN12E for proper connection and correct or change as necessary. (bizhub C458)
  5. Check the connector between TEMS/1-relay CN109-MFPB CN15E for proper connection and correct as necessary. (bizhub C658/C558)
  6. Check the connector between TEMS/2-relay CN138-MFPB CN15E for proper connection and correct as necessary. (bizhub C658/C558)
  7. Replace the fusing unit. (bizhub C658/C558 Part# A79JR71066/ bizhub C458 Part# A79MR70222)
  8. Replace IHPU. (bizhub C658/C558 only) (Part# A8KNM40A02)
  9. Replace FUPU. (bizhub C458 only) (Part# A79MM40N00)
  10. Replace MFPB. (C458 Part# A79MH02102 / C558 or C658 Part # A79JH02102)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.14.6 (Link to the Field Service Manual)