How Can We Help?

C3722 (bizhub 287/227)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeC3722: Fusing abnormally high temperature detection (Edge of the heating roller)
RankA
Trouble detection conditionDetected temperature of the thermistor/2 (TH2) goes beyond a given temperature for a given period of time consecutively
Trouble isolation
Relevant electrical parts-Fusing unit
-Thermistor/2 (TH2)
-MFP board (MFPB)

 Procedure

  1. Check the fusing unit for correct installation (whether it is secured in position).
  2. Check the open/close operation of the right door.
  3. Check the connector between the fusing unit-relay CN19-MFPB CN18E for proper connection and correct as necessary.
  4. Replace the fusing unit. (Part# A7AHR72311 or A7AHPP3800(For refresh model))
  5. Replace MFPB. (Part# A7AHH0201D)

K.3.10.2 (Link to the Field Service Manual)

Table of Contents