C3731 (bizhub 287/227)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C3731: Fusing abnormally high temperature detection (Hard protector) |
Rank | A |
Trouble detection condition | The hard protector signal error is detected for a given period of time consecutively. |
Trouble isolation | – |
Relevant electrical parts | -Fusing unitThermistor/1 (TH1) -Thermistor/2 (TH2) -MFP board (MFPB) |
Procedure
- Check the fusing unit for correct installation (whether it is secured in position).
- Check the open/close operation of the right door.
- Check the connector between the fusing unit-relay CN19-MFPB CN18E for proper connection and correct as necessary.
- Replace the fusing unit. (Part# A7AHR72311 or A7AHPP3800(For refresh model))
- MFPB F3E conduction check
- Replace MFPB. (Part# A7AHH0201D)
K.3.10.3 (Link to the Field Service Manual)