C3725 (bizhub 658e/558e/458e)

You are here:

Contents

Trouble typeC3725: Fusing abnormally high temperature detection (Main of the heating roller)
RankA
Trouble detection conditionDetected temperature of the heating roller temperature sensor/1 (TEMS/1) or heating roller temperature sensor (TEMS) goes beyond a given temperature for a given period of time consecutively.
Trouble isolation
Relevant electrical parts• Fusing unit 
• (bizhub 658e/558e): Heating roller temperature sensor/1 (TEMS/1), (bizhub 458e): Heating roller temperature sensor (TEMS)
• IH power supply (IHPU) (bizhub 658e/558e only) 
• Fusing power supply (FUPU) (bizhub 458e) 
• MFP board (MFPB)

 Procedure

  1. Check the fusing unit for correct installation (whether it is secured in position).
  2. Check the open/close operation of the right door.
  3. Check the fusing unit-MFPB CN22E for proper connection and correct or change as necessary. (bizhub 658e/558e)
  4. Check the fusing unit-MFPB CN12E for proper connection and correct or change as necessary. (bizhub 458e)
  5. Check the connector between TEMS/1-relay CN109-MFPB CN15E for proper connection and correct as necessary. (bizhub 658e/558e)
  6. Replace the fusing unit. (bizhub 658e/558e Part# A79JR71077 / bizhub 458e Part# AA6UR70400)
  7. Replace IHPU. (bizhub 658e/558e only) (Part# A8KNM40A02)
  8. Replace FUPU. (bizhub 458e only) (Part# A79MM40N00)
  9. Replace MFPB. (658e/558e Part# AA6RH02103 / 458e Part# AA6UH02101)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

L.3.12.6 (Link to the Field Service Manual)