C3725 (bizhub 658e/558e/458e)
Contents
Trouble type | C3725: Fusing abnormally high temperature detection (Main of the heating roller) |
Rank | A |
Trouble detection condition | Detected temperature of the heating roller temperature sensor/1 (TEMS/1) or heating roller temperature sensor (TEMS) goes beyond a given temperature for a given period of time consecutively. |
Trouble isolation | – |
Relevant electrical parts | • Fusing unit • (bizhub 658e/558e): Heating roller temperature sensor/1 (TEMS/1), (bizhub 458e): Heating roller temperature sensor (TEMS) • IH power supply (IHPU) (bizhub 658e/558e only) • Fusing power supply (FUPU) (bizhub 458e) • MFP board (MFPB) |
Procedure
- Check the fusing unit for correct installation (whether it is secured in position).
- Check the open/close operation of the right door.
- Check the fusing unit-MFPB CN22E for proper connection and correct or change as necessary. (bizhub 658e/558e)
- Check the fusing unit-MFPB CN12E for proper connection and correct or change as necessary. (bizhub 458e)
- Check the connector between TEMS/1-relay CN109-MFPB CN15E for proper connection and correct as necessary. (bizhub 658e/558e)
- Replace the fusing unit. (bizhub 658e/558e Part# A79JR71077 / bizhub 458e Part# AA6UR70400)
- Replace IHPU. (bizhub 658e/558e only) (Part# A8KNM40A02)
- Replace FUPU. (bizhub 458e only) (Part# A79MM40N00)
- Replace MFPB. (658e/558e Part# AA6RH02103 / 458e Part# AA6UH02101)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
L.3.12.6 (Link to the Field Service Manual)