Trouble typeFusing abnormally high temperature detection (Center of the heating side)
Trouble codeC3726
RankA
Detection timingDetected temperature of the heating roller thermistor/2 (TH2) goes beyond a given temperature for a given period of time consecutively.
Trouble isolation
Relevant electrical parts• Fusing unit 
• Heating roller thermistor/1 (TH1) 
• IH power supply (IHPU) (bizhub 554e only) 
• Printer control board (PRCB)

  (2)Procedure

StepActionControl signalLocation of electrical components
1Check the fusing unit for correct installation (whether it is secured in position).
2Check the open/close operation of the right door.
3Check the fusing unit, IHPU (bizhub 554e only) and PRCB for proper connection and correct or change as necessary.
4Replace the fusing unit (bizhub 554e/bizhub 454e) Fusing Unit (Part# 545e A2XKR71022 454e A4FJR70322)
5Replace IHPU (bizhub 554e only)IHPU (Part# 554e 100v A61DM40A00 230v A61DM40B00)
6Replace PRCBPRCB (Part# 554e A61DH00101 454e A61EH00101)
  • Link to the layout drawings for related parts by each trouble code (S.70. C3722)
  • Link to the layout drawings for related parts by each trouble code (S.71. C3725, C3825)
  • Link to the layout drawings for related parts by each trouble code (S.72. C3726)