C3726 (bizhub 958/808)
Contents
Trouble type | C3726: Fusing abnormally high temperature detection (Center of the heating roller) |
Rank | A |
Trouble detection condition | C3726: Detected temperature of the fusing belt temperature sensor/2 (TEMS2) goes beyond a given temperature for a given period of time consecutively. |
Trouble isolation | – C3726: Detected temperature of the heating roller temperature sensor/2 (TEMS2) goes beyond a given temperature for a given period of time consecutively. |
Relevant electrical parts | • Fusing Unit • C3726: Fusing belt temperature sensor/2 (TEMS2) (bizhub 958, bizhub PRO 958) • C3726: Heating roller temperature sensor/2 (TEMS2) (bizhub 808/758) • IH power supply unit (IHPU) • Noise filter (NF1) • MFP board (MFPB) |
Procedure
- Check the fusing unit for correct installation (whether it is secured in position).
- Check the open/close operation of the upper right door.
- Check the fusing unit-MFPB CN30E for proper connection and correct or change as necessary.
- Check the connector between TEMS1, TEMS2, TEMS3-relay CN512-MFPB CN29E for proper connection and correct as necessary.
- Check the connector between NF1 CN2-IHPU CN1 for proper connection and correct as necessary.
- Check the connector between IHPU CN8-MFPB CN18E for proper connection and correct as necessary.
- Replace the fusing unit. ( 958)A796R71422 )( 808)A795R72922 )
- Replace IHPU. (958)( A796M40B00 )(808)( A8KNM40A02 )
- Replace MFPB. ( A796H02003)
- Replace NF1. (958)( A796M40H00 )(808)( A795M40J00 )
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
(Link to the Field Service Manual) K.3.9.10.