C3731 (bizhub 958/808)

You are here:

Contents

Trouble typeC3731: Fusing abnormally high temperature (Hard protector)
RankA
Trouble detection conditionAn abnormally high temperature of the hard protector signal is detected.
Trouble isolation
Relevant electrical parts• Fusing unit
• Fusing belt temperature sensor/1 (TEMS1) (bizhub 958, bizhub PRO 958)
• Heating roller temperature sensor/1 (TEMS1) (bizhub 808/758)
• Fusing belt temperature sensor/2 (TEMS2) (bizhub 958, bizhub PRO 958)
• Heating roller temperature sensor/2 (TEMS2) (bizhub 808/758)
• Fusing belt temperature sensor/3 (TEMS3) (bizhub 958, bizhub PRO 958)
• Heating roller temperature sensor/3 (TEMS3) (bizhub 808/758)
• Pressure roller thermistor/2 (TH3)
• MFP board (MFPB)

 Procedure

  1. Check the fusing unit for correct installation (whether it is secured in position).
  2. Check the open/close operation of the upper right door.
  3. Check the fusing unit-MFPB CN30E for proper connection and correct or change as necessary.
  4. Check the connector between TEMS1, TEMS2, TEMS3-relay CN512-MFPB CN29E for proper connection and correct as necessary.
  5. Replace the fusing unit. ( A796R71422 )
  6. Replace TEMS1, TEMS2, TEMS3. (A796M50000)
  7.  Replace MFPB. ( A796H02003)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

(Link to the Field Service Manual) K.3.9.12.