Trouble type Fusing abnormally low temperature detection (Main of the heating roller)
Trouble code C3825
Rank A
Detection timing The heating roller temperature sensor (TEMS) continues to detect a temperature lower than a predetermined one for a predetermined period of time.
Trouble isolation
Relevant electrical parts• Fusing unit
• Heating roller temperature sensor (TEMS)
• IH power supply (IHPU) (bizhub 554e only)
• Printer control board (PRCB)

  (2)Procedure

Step Action Control signal Location of electrical components
1 Check the fusing unit for correct installation (whether it is secured in position).
2 Check the open/close operation of the upper right door.
3 Check the fusing unit, IHPU (bizhub 554e only) and PRCB for proper connection and correct or change as necessary.
4 Replace the fusing unit (bizhub 554e/bizhub 454e) Fusing Unit (Part# 545e A2XKR71022 454e A4FJR70322)
5 Replace IHPU (bizhub 554e only)IHPU (Part# 554e 100v A61DM40A00 230v A61DM40B00)
6 PRCB ICP15 conduction check
7 Replace PRCBPRCB (Part# 554e A61DH00101 454e A61EH00101)
  • Link to the layout drawings for related parts by each trouble code (S.71. C3725, C3825)