Trouble typeC3825: Fusing abnormally low temperature detection (Main of the heating roller)
RankA
Trouble detection conditionThe heating roller temperature sensor (TEMS) continues to detect a temperature lower than a predetermined one for a predetermined period of time.
Trouble isolation
Relevant electrical parts-Fusing unit
-Heating roller temperature sensor (TEMS)
-DC power supply (DCPU)
-MFP board (MFPB)

 Procedure

  1. Check the fusing unit for correct installation (whether it is secured in position).
  2. Check the open/close operation of the right door.
  3. Check the connector between the fusing unit-relay CN4-MFPB CN16E for proper connection and correct as necessary.
  4. Replace the fusing unit. (Part# A797R70211)
  5. Replace DCPU. (Part# A797R70800)
  6. Replace MFPB. (Part# A797H02118)

K.3.10.6 (Link to the Field Service Manual)