C3826 (bizhub 558/458)

You are here:

Contents

Trouble typeC3826: Fusing abnormally low temperature detection (Center of the heating side) (bizhub 458)
RankA
Trouble detection conditionThe heating roller thermistor 2 (TH2) continues to detect a temperature lower than a predetermined one for a predetermined period of time.
Trouble isolation
Relevant electrical parts• Fusing unit 
• Heating roller thermistor 2 (TH2)
• IH power supply (IHPU) (bizhub 558 only) 
• MFP board (MFPB)

 Procedure

  1. Check the fusing unit for correct installation (whether it is secured in position).
  2. Check the open/close operation of the right door.
  3. Check the fusing unit-MFPB CN22E for proper connection and correct or change as necessary. (bizhub 558)
  4. Check the fusing unit-MFPB CN12E for proper connection and correct or change as necessary. (bizhub 458)
  5. Check the connector between TEMS/1-relay CN109-MFPB CN15E for proper connection and correct as necessary. (bizhub 558)
  6. Replace the fusing unit. (bizhub 558 Part# A9E8030 / bizhub 458 Part# A79MR70200)
  7. Replace IHPU. (bizhub 558 only)(Part# A8KNM40A02)
  8. MFPB F12E conduction check
  9. Replace MFPB. (558 Part# A9HGH02102 / 458 Part# A9HHH02102)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.13.8 (Link to the Field Service Manual)