How Can We Help?

C3922 (bizhub 558/458)

You are here:

Contents

Trouble typeC3922: Fusing sensor wire breaks detection (Edge of the heating side)
RankA
Trouble detection conditionAfter a predetermined period of time after the warm-up stage is started, the heating roller thermistor 1 (TH1) voltage does not decrease by predetermined steps (temperature rise) within a predetermined period of time.
Trouble isolation
Relevant electrical parts• Fusing unit
• Heating roller thermistor 1 (TH1)
• IH power supply (IHPU) (bizhub 558 only)
• MFP board (MFPB)

 Procedure

  1. Check the fusing unit for correct installation (whether it is secured in position).
  2. Check the open/close operation of the right door.
  3. Check the fusing unit-MFPB CN22E for proper connection and correct or change as necessary. (bizhub 558)
  4. Check the fusing unit-MFPB CN12E for proper connection and correct or change as necessary. (bizhub 458)
  5. Check the connector between TEMS/1-relay CN109-MFPB CN15E for proper connection and correct as necessary. (bizhub 558)
  6. Replace the fusing unit. (bizhub 558 Part# A9E8030 / bizhub 458 Part# A79MR70200)
  7. Replace IHPU. (bizhub 558 only)(Part# A8KNM40A02)
  8. MFPB F12E conduction check
  9. Replace MFPB. (558 Part# A9HGH02102 / 458 Part# A9HHH02102)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.13.9 (Link to the Field Service Manual)

Table of Contents