C3826 (bizhub C3320i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C3826: Fusing abnormally low temperature detection (Center of the heating roller) |
Rank | A |
Trouble detection condition | The heating roller thermistor/Ctr (TH2) continues to detect a temperature lower than a predetermined one for a predetermined period of time. |
Trouble isolation | – |
Relevant electrical parts | -Fusing unit -Heating roller temperature sensor (TEMS) -DC power supply (DCPS) -CPU board (CPUB) -Base board (BASEB) |
Procedure
- Check the fusing unit for correct installation (whether it is secured in position).
- Check the open/close operation of the right door.
- Check the connector between the fusing unit-relay CN3-BASEB CN10E for proper connection and correct as necessary.
- Check the connector between the fusing unit-relay CN2-DCPS CN2 for proper connection and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- Replace the fusing unit. (Part# AAJRR70300)
- Replace CPUB. (Part# AAJRH01005)
- Replace BASEB. (Part# A93EH02007)
- DCPS F102 or FU181 conduction check.
- Replace DCPS. (Part# AAJRR70600)
L.3.8.5 (Link to the Field Service Manual)