Trouble typeC3922: Fusing sensor wire breaks detection (Edge of the heating roller)
RankA
Trouble detection conditionC3922: The maximum value and minimum value of detected temperature of the heating roller thermistor/Edg (TH1) is compared after a lapse of given time from starting of warm up and the gap between the value of maximum and minimum is below or above given temperatures.
Trouble isolation
Relevant electrical parts-Fusing unit
-Heating roller thermistor/Edg (TH1)
-DC power supply (DCPS)
-CPU board (CPUB)
-Base board (BASEB)

Procedure

  1. Check the fusing unit for correct installation (whether it is secured in position).
  2. Check the open/close operation of the right door.
  3. Check the connector between the fusing unit-relay CN3-BASEB CN10E for proper connection and correct as necessary.
  4. Check the connector between the fusing unit-relay CN2-DCPS CN2 for proper connection and correct as necessary.
  5. Check CPUB for proper installation and correct as necessary.
  6. Replace the fusing unit. (Part# AAJRR70300)
  7. Replace CPUB. (Part# AAJRH01005)
  8. Replace BASEB. (Part# A93EH02007)
  9. DCPS F102 or FU181 conduction check.
  10. Replace DCPS. (Part# AAJRR70600)

L.3.8.6 (Link to the Field Service Manual)