How Can We Help?

C3826 (bizhub C360i/C300i/C250i)

You are here:

Contents

Trouble typeC3826: Fusing abnormally low temperature detection (Center of the heating roller)
RankA
Trouble detection conditionThe heating roller thermistor/Ctr (TH2) continues to detect a temperature lower than a predetermined one for a predetermined period of time.
Trouble isolation
Relevant electrical parts• Fusing unit
• Heating roller thermistor/Ctr (TH2)
• CPU board (CPUB)
• Base board (BASEB)

Procedure

  1. Check the fusing unit for correct installation (whether it is secured in position).
  2. Check the open/close operation of the right door.
  3. Check the connector between the fusing unit-relay CN95-BASEB CN4E for proper connection and correct as necessary.
  4. Check CPUB for proper installation and correct as necessary.
  5. Replace the fusing unit. (Part# AA2JR70300)
  6. Replace CPUB. (Part# AA2JH02N06)
  7. Replace BASEB. (Part# AA2JH02005)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

L.3.9.7 (Link to the Field Service Manual)

Table of Contents