How Can We Help?

C3922 (bizhub 554e/454e)

You are here:

Contents

Trouble type Fusing sensor wire breaks detection (Edge of the heating roller)
Trouble code C3922
Rank A
Detection timing After a predetermined period of time after the warm-up stage is started, the heating roller thermistor/1 (TH1) voltage does not decrease by predetermined steps (temperature rise) within a predetermined period of time.
Trouble isolation
Relevant electrical parts• Fusing unit
• Heating roller thermistor/1 (TH1)
• Printer control board (PRCB)

  (2)Procedure

Step Action Control signal Location of electrical components
1 Check the fusing unit for correct installation (whether it is secured in position).
2 Check the open/close operation of the upper right door.
3 Check the fusing unit and PRCB for proper connection and correct or change as necessary.
4 Replace the fusing unit (bizhub 554e/bizhub 454e) Fusing Unit (Part# 545e A2XKR71022 454e A4FJR70322)
5 Replace PRCBPRCB (Part# 554e A61DH00101 454e A61EH00101)
  • Link to the layout drawings for related parts by each trouble code (S.75. C3922)
  • Link to the layout drawings for related parts by each trouble code (S.76. C3925)
  • Link to the layout drawings for related parts by each trouble code (S.77. C3926)

Document Information ID D0001134379 Revise ID R000003