C3926 (bizhub C658/C558/C458)

You are here:

Contents

Trouble typeC3926: Fusing sensor wire breaks detection (Center of the heating roller)
RankA
Trouble detection conditionAfter a predetermined period of time after the warm-up stage is started, the heating roller thermistor2 (TH2) voltage does not decrease by predetermined steps (temperature rise) within a predetermined period of time.
Trouble isolation
Relevant electrical parts• Fusing unit 
• Heating roller thermistor2 (TH2) 
• IH power supply (IHPU) (bizhub C658/C558/C458 only) 
• MFP board (MFPB)

 Procedure

  1. Check the fusing unit for correct installation (whether it is secured in position).
  2. Check the open/close operation of the right door.
  3. Check the fusing unit-MFPB CN22E for proper connection and correct or change as necessary. (bizhub C658/C558)
  4. Check the fusing unit-MFPB CN12E for proper connection and correct or change as necessary. (bizhub C458)
  5. Check the connector between TEMS/1-relay CN109-MFPB CN15E for proper connection and correct as necessary. (bizhub C658/C558)
  6. Check the connector between TEMS/2-relay CN138-MFPB CN15E for proper connection and correct as necessary. (bizhub C658/C558)
  7. Replace the fusing unit. (bizhub C658/C558 / bizhub C458)
  8. Replace IHPU. (bizhub C658/C558 only) (Part# A8KNM40A02)
  9. MFPB F12E conduction check
  10. Replace MFPB. (C458 Part# A79MH02102 / C558 or C658 Part # A79JH02102)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.14.9 (Link to the Field Service Manual)