Trouble typeC392A: Heating roller temperature sensor contamination (Main of the heating roller)
RankC
Trouble detection conditionDuring waiting after a predetermined period of time after the warm-up stage terminates, the temperature detected by the heating roller thermostat3 (TH3) exceeds that detected by the heating roller temperature sensor1 (TEMS/1) above a predetermined temperature, and this state continues for a predetermined period of time.
Trouble isolation
Relevant electrical parts• Fusing unit
• Heating roller temperature sensor1 (TEMS/1)
• Heating roller thermistor3 (TH3)
• MFP board (MFPB)

 Procedure

  1. Wipe the TEMS/1 clean of dirt if any.
  2. <Cleaning procedure>
    • Clear away a dirt or a foreign object on the sensor with a cotton swab.
    • When a dirt is left even if you cleaned the sensor by above procedure, clear away a dirt or a foreign object on the sensor using a cotton swab dampened with the alcohol. And, wipe off the sensor with a dry cotton swab afterwards.
  3. Check the TEMS/1 for installed position and proper connector connection.
  4. Check the connection of the fusing unit.
  5. Check the fusing unit-MFPB CN22E for proper connection and correct or change as necessary.
  6. Check the connector between TEMS/1-relay CN109-MFPB CN15E for proper connection and correct as necessary.
  7. Replace the fusing unit. ((bizhub C658/C558) Part# A79JR71066 (bizhub C458) Part# A79MR70222)
  8. Replace MFPB. (C458 Part# A79MH02102 / C558 or C658 Part # A79JH02102)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.14.10 (Link to the Field Service Manual)