C392A (bizhub 558/458)
Contents
Trouble type | C392A: Heating roller temperature sensor contamination (Main of the heating side) (bizhub 558) |
Rank | C |
Trouble detection condition | During waiting after a predetermined period of time after the warm-up stage terminates, the temperature detected by the heating roller thermostat3 (TH3) exceeds that detected by the heating roller temperature sensor 1 (TEMS/1) above a predetermined temperature, and this state continues for a predetermined period of time. |
Trouble isolation | – |
Relevant electrical parts | • Fusing unit • Heating roller temperature sensor 1 (TEMS/1) • Heating roller thermistor 3 (TH3) • MFP board (MFPB) |
Procedure
- Wipe the TEMS/1 clean of dirt if any.
- <Cleaning procedure>
- Clear away a dirt or a foreign object on the sensor with a cotton swab.
- When a dirt is left even if you cleaned the sensor by above procedure, clear away a dirt or a foreign object on the sensor using a cotton swab dampened with the alcohol. And, wipe off the sensor with a dry cotton swab afterwards.
- Check the TEMS/1 for installed position and proper connector connection.
- Check the connection of the fusing unit.
- Check the fusing unit-MFPB CN22E for proper connection and correct or change as necessary.
- Check the connector between TEMS/1-relay CN109-MFPB CN15E for proper connection and correct as necessary.
- Replace the fusing unit. (558 Part# A9E8030 / 458 Part# A79MR70200)
- Replace MFPB. (558 Part# A9HGH02102 / 458 Part# A9HHH02102)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.13.10 (Link to the Field Service Manual)