C392B (bizhub 558/458)
Contents
Trouble type | C392B: Fusing sensor wire breaks detection (difference of temperature) |
Rank | A |
Trouble detection condition | The difference between the temperature corrected by the heating roller thermistor 1 (TH1) and the temperature detected by the heating roller thermistor 2 (TH2) exceeds a predetermined value. |
Trouble isolation | – |
Relevant electrical parts | • Fusing unit • Heating roller thermistor 1 (TH1) • Heating roller thermistor 2 (TH2) • MFP board (MFPB) |
Procedure
- Check the fusing unit for correct installation (whether it is secured in position).
- Check the open/close operation of the right door.
- Check the fusing unit-MFPB CN22E for proper connection and correct or change as necessary. (bizhub 558)
- Check the fusing unit-MFPB CN12E for proper connection and correct or change as necessary. (bizhub 458)
- Replace the fusing unit. (bizhub 558 Part# A9E8030 / bizhub 458 Part# A79MR70200)
- Replace MFPB. (558 Part# A9HGH02102 / 458 Part# A9HHH02102)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.13.11 (Link to the Field Service Manual)