C3B03 (bizhub 554e/454e)
Contents
Trouble type | IH malfunction (monitor) | |
Trouble code | C3B03 | |
Rank | A | |
Detection timing | <bizhub 554e> | Though the IH heater is OFF, mechanically, the ON status is detected. (Malfunction of IH heater operation) |
Trouble isolation | – | |
Relevant electrical parts | • Fusing unit • IH coil unit (IHC) • IH magnetic erasing board (IHMEB) • Printer control board (PRCB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | Check the fusing unit for correct installation (whether it is secured in position). | – | – |
2 | Check the open/close operation of the upper right door. | – | – |
3 | Check the fusing unit, IHC, IHPU, IHMEB and PRCB for proper connection and correct or change as necessary. | – | – |
4 | Replace the fusing unitFusing Unit (Part# 545e A2XKR71022 454e A4FJR70322) | – | – |
5 | Replace IHC | – | – |
6 | Replace IHPUIHPU (Part# 554e 100v A61DM40A00 230v A61DM40B00) | – | – |
7 | Replace IHMEBIHMEB (Part# 554e A2XKH00A00) | – | – |
8 | Replace PRCBPRCB (Part# 554e A61DH00101 454e A61EH00101) | – | – |
- Link to the layout drawings for related parts by each trouble code (S.79. C3B02, C3B03)