Trouble type IH input power error
Trouble code C3B07
Rank A
Detection timing <bizhub 554e>
• While the IH heater was ON, input power stayed at the high voltage power detection value or over for more than the predetermined period of time.
• While the IH heater was ON, input power was at the low power detection value or under for more than the predetermined period of time.
• While the IH heater was ON, input power was at the high voltage detection value or over for more than the predetermined period of time.
• While the IH heater was ON, input power was below the low voltage detection value or under for more than the predetermined period of time.
• While the IH heater was ON, inverter power stayed at the upper limit value or over for more than the predetermined period of time.
• While the IH heater was ON, output voltage halt was detected.
Trouble isolation
Relevant electrical parts• IH coil unit (IHC)
• IH power supply (IHPU)
• Printer control board (PRCB)

  (2)Procedure

Step Action Control signal Location of electrical components
1 Check the connection of the fusing unit.
2 Check the fusing unit, IHC, IHPU and PRCB for proper connection and correct or change as necessary.
3 Replace IHC (Part# A2XKM40C01)
4 Replace IHPU (Part# A61DM40A00)
5 Replace PRCB (554e Part# A61EH00101 / 454e Part# A61DH00101)