Trouble typeC3B03: IH malfunction (monitor) / Incorrect marketing area (bizhub 658e/558e)
RankA
Trouble detection condition• Though the IH heater is OFF, mechanically, the ON status is detected. (Malfunction of IH heater operation)
• The marketing areas of the fusing unit and the IH power supply is different.
Trouble isolation
Relevant electrical parts• Fusing unit
• IH coil (IHC) 
• IH power supply (IHPU) 
• IH magnetic erasing board (IHMEB) 
• NF board (NFB) 
• MFP board (MFPB)

 Procedure

  1. Check the fusing unit for correct installation (whether it is secured in position).
  2. Check the open/close operation of the right door.
  3. Check the fusing unit-MFPB CN22E for proper connection and correct or change as necessary.
  4. Check the connector between MFPB CN13E-NFB CN3 for proper connection and correct as necessary.
  5. Check the connector between NFB CN2-IHPU CN1 for proper connection and correct as necessary.
  6. Check the connector between IHPU-IHC for proper connection and correct as necessary.
  7. Check the connector between IHC-IHMEB for proper connection and correct as necessary.
  8. Check the marketing area of the fusing unit and IHPU.
  9. If the marketing area is incorrect, replace them for proper marketing area.
  10. Replace the fusing unit. (Part# A79JR71077)
  11. Replace IHC. (Part# A79JM40C00)
  12. Replace IHPU. (Part# A8KNM40A02)
  13. Replace IHMEB. (658e Part# A2XKH00A00 / 558e Part# A796H00W00)
  14. Replace NFB. (Part# A795M40J00)
  15. Replace MFPB. (Part# AA6RH02103)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.