C3B07 (bizhub 658e/558e)
Contents
Trouble type | C3B07: IH input power error (bizhub 658e/558e) |
Rank | A |
Trouble detection condition | • While the IH heater was ON, input power stayed at the high voltage power detection value or over for more than the predetermined period of time. • While the IH heater was ON, input power was at the low power detection value or under for more than the predetermined period of time. • While the IH heater was ON, input power was at the high voltage detection value or over for more than the predetermined period of time. • While the IH heater was ON, input power was below the low voltage detection value or under for more than the predetermined period of time. • While the IH heater was ON, inverter power stayed at the upper limit value or over for more than the predetermined period of time. • While the IH heater was ON, output voltage halt was detected. |
Trouble isolation | – |
Relevant electrical parts | • Fusing unitIH coil (IHC) • IH power supply (IHPU) • NF board (NFB) • MFP board (MFPB) |
Procedure
- Check the fusing unit for correct installation (whether it is secured in position).
- Check the fusing unit-MFPB CN22E for proper connection and correct or change as necessary.
- Check the connector between NFB CN2-IHPU CN1 for proper connection and correct as necessary.
- Check the connector between IHPU CN8-MFPB CN3E for proper connection and correct as necessary.
- Replace IHC. (Part# A79JM40C00)
- Replace IHPU. (Part# A8KNM40A02)
- Replace NFB. (Part# A795M40J00)
- Replace MFPB. (Part# AA6RH02103)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
L.3.12.13 (Link to the Field Service Manual)