How Can We Help?

C3B03 (bizhub 754e/654e)

You are here:

Contents

Trouble typeIH malfunction (monitor)
Trouble codeC3B03
RankA
Detection timing• Though the IH heater is ON, this status cannot be detected mechanically. (IH heater operation failure)
• Though the IH heater is OFF, mechanically, the ON status is detected. (Malfunction of IH heater operation)
Trouble isolation
Relevant electrical parts• Fusing unit 
• IH coil unit (IHC) 
• IH power supply (IHPU) 
• IH magnetic erasing board (IHMEB) 
• Noise filter (NF1) 
• Printer control board (PRCB)

  (2)Procedure

StepActionControl signalLocation of electrical components
1Check the fusing unit for correct installation (whether it is secured in position).
2Check the open/close operation of the upper right door.
3Check the fusing unit, IHC, IHPU, IHMEB, NF1 and PRCB for proper connection and correct or change as necessary.
4Check the marketing area of IHPU. 
If the marketing area is incorrect, replace IHPU for proper marketing area.
5Replace the fusing unit (Other area except Taiwan) (Part# A2X0R71055)
6Replace IHC (Part# A2X0M40200)
7Replace IHPU (Part# A61DM40A00)
8Replace IHMEB (Part# A2X0H00W02)
9PRCB ICP15 conduction check
10Replace PRCBPRCB (Part# A55VH00105)
11Replace NF1 (Part# A2XKM40J00 )

Document Information ID D0001104786 Revise ID R000004