How Can We Help?

C4002 (bizhub C759/C659)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeC4002: PH communication error
RankC
Trouble detection conditionWhen the PH relay board (PHRYB) is receiving data, a communication error is detected.
Trouble isolation
Relevant electrical parts-PH relay board (PHRYB)
-MFP board (MFPB)

 Procedure

  1. Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch.
  2. Check the connector between MFPB CN6E-PHRYB CN8 for proper connection and correct as necessary.
  3. Check the connector between MFPB CN5E-PHRYB CN9 for proper connection and correct as necessary.
  4. Rewrite the firmware.
  5. PHRYB ICP1 conduction check.
  6. Replace PHRYB. (Part# A8JEH00301)
  7. MFPB F2E conduction check
  8. Replace MFPB. (Part# A8JEH02002)

L.3.11.1 (Link to the Field Service Manual)