How Can We Help?
C40A2, C40A3, C40A4, C40A4, C40A5, C40A6, C40C3, C40C5 (bizhub 950i/850i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | – C40A2: Mechanical controller PF communication data error – C40A3: Mechanical controller PF transmission timeout – C40A4: Mechanical controller PF communication pulse error -C40A5: QSPI communication clock switching error – C40A6: Mechanical controller ASIC communication error – C40C3: CTL PF transmission timeout 1 – C40C5: CTL PF transmission timeout 2 |
Rank | C |
Trouble detection condition | A CPU communication error is detected. |
Trouble isolation | – |
Relevant electrical parts | – CPU board (CPUB) – Base board (BASEB) |
Procedure
- Turn OFF the main power switch and unplug the power cord. Connect the power cord after 15 sec. or more, and turn ON the main power switch.
- Check CPUB for proper installation and correct as necessary.
- Rewrite the firmware.
- Replace CPUB.
- BASEB F2E conduction check.
- Replace BASEB.