How Can We Help?

C4101(bizhub 958/808)

You are here:

 Contents

Trouble typeC4101:
• Polygon motor rotation trouble
• PH unit for incorrect marketing area
RankB
Trouble detection condition• The polygon motor fails to turn stably even after the lapse of a given period of time after activating the polygon motor.
• Motor lock signal detects HIGH for a given period time consecutively during the polygon motor is rotating.
• The PH unit for incorrect marketing area is installed.
Trouble isolation
Relevant electrical parts• PH unit
• PH relay board (PHRYB)
• MFP board (MFPB)

 Procedure

  1. Check the type of the installed PH unit and replace it if it is a wrong one.
  2. Check the connector between the PH unit-PHRYB CN3 for proper connection and correct as necessary.
  3. Replace the PH unit. (Part# A796R70500)
  4. PHRYB F3 conduction check.
  5. Replace PHRYB. (Part# A796H00300)
  6. Replace MFPB. (Part# A796H02003)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.10.3 (Link to the Field Service Manual)

Table of Contents