How Can We Help?

C4301 (bizhub C754/C654)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typePH cooling fan’s failure to turn
Trouble codeC4301
RankB
Detection timingThe fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Trouble isolation
Relevant electrical parts-PH cooling fan (FM14)
-PH relay board (PHRYB)
-Printer control board (PRCB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Check the connector between FM14-relay CN202-PHRYB CN12 for proper connection and correct as necessary.
2Check the fan for possible overload and correct as necessary.
3FM14 operation checkPHRYB CN12-4 (DRIVE)PHRYB CN12-5 (LOCK)9-B
4Replace FM14 (Part# 9J03M10000)
5PHRYB ICP6 conduction check
6Replace PHRYB (Part# A2X0H00300)
7Replace PRCB (Part# A2X0H00102)

K.3.9.3 (Link to the Field Service Manual)