How Can We Help?

C4301 (bizhub C759/C659)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeC4301: PH cooling fan failure to turn
RankB
Trouble detection conditionThe fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Trouble isolation
Relevant electrical parts-PH cooling fan (FM14)
-PH relay board (PHRYB)

 Procedure

  1. Check the connector between FM14-relay CN202-PHRYB CN12 for proper connection and correct as necessary.
  2. Check the fan for possible overload and correct as necessary.
  3. FM14 load check
    • Check code: 42
    • Multi code: 20, 21
    • Control signal: PHRYB CN12-4 (DRIVE), PHRYB CN12-5 (LOCK)
    • Location of electrical component: 8-B
  4. Replace FM14. (Part# A03UM15300)
  5. PHRYB ICP6 conduction check.
  6. Replace PHRYB. (Part# A8JEH00301)

L.3.11.4 (Link to the Field Service Manual)

Table of Contents